Dialysate

The main control console of the centralized feeding system strictly adjusts the flow rate and proportion of the raw materials in the inner and outer layers according to the set parameters.
With the HQ screw series, it exceeds the extrusion capacity of the peer by more than 30%, precise production control, small product weight fluctuations during the production process, and multi-layer co-extrusion process.
Adopt a blow molding machine with a forced feeding trough, multiple safety pressure protection devices, and more than 50 years of experience in multi-layer co-extrusion.
Accurate detection of particulate pollution and microbial limits.

classification:

Medicine bucket2

seo:

Product Details

Has been committed to ultra clean dialysate barrel!

Dialysate barrel specifications

 

VolumeWeightDimensionsColor
( L )gMaximum DiameterHeightmouth diameter 
5280±10194×162±3250±344±0.3White
6320±10194×162±3274±344±0.3White
A10518±10234×192±5290±544±0.3White
B10540±20225×190±5326±545±0.3White
A12610±10250×197±5329±544±0.3White
B12610±20225×200±5345±545±0.3White
251500±5017×279±5393±547±1.0White

 

Packaging materialsBiocompatibility

☆The barrel body and lid material meet the biocompatibility requirements of China and the world (ISO 10993 series or GB/T 16886 series) to avoid toxin contamination concentrate and ensure the safety of dialysis treatment for patients

☆Microbial pollution control: the total number of aerobic bacteria shall not exceed 50CFU/barrel, the total number of molds and yeasts shall not exceed 50CFU/barrel, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa shall not be detected

☆Particle control: ≥ 10μm particles are not more than 6/ml; ≥ 25 μm particles are not larger than 1 / ml

 

TestReference standards
CytotoxicityISO 10993-5:2009(E)
Sensitization experimentsISO 10993-10:2010(E)
Intradermal reactions10993-10:2010(E)
Acute systemic toxicityISO 10993-11:2017(E)
Blood compatibilityASTM F756
Substance-mediated pyrogenicityChienese pharmacopoeia volume IV <1142>
USP<151>
Chemical characterizationISO 10993-18:2020(E)


Dialysate barrel quality standards
 

projectQuality standards
appearance

It should have a uniform and consistent color, no obvious color difference, and the surface should be smooth, flat, without deformation and obvious scratches.

There must be no trachoma, oil, holes, bubbles; The number of black dots is not more than 3, and the black dots are scattered and do not affect the use;

Penetrating impurities are not allowed. The inner surface of the barrel must not have any falling impurities

Net weight(g)5L:290-310g;6L:300-320g;10L:515-545g;12L:585-615g
Wall thicknessMinimum wall thickness≥ 0.8
Peripheral tendon ≥ 0.8
Stacking contact surface ≥ 1.3
Brimful capacityThe barrel mouth should be flat and smooth, and the convex ribs of the barrel mouth should not be omitted; The face of the barrel mouth is flat and smooth, without burrs or bumps exceeding 0.5mm;
Black spot impurities

The number of black dots is no more than 3; The black dots should be scattered and distributed without affecting the use; Penetrating impurities are not allowed.

The inner surface of the barrel must not have any impurities that can be dropped

Full mouth volume ml5L:5850-6200;6L:6600-6950mL;10L:10400-11000mL;12L;12500-13100mL
Barrel mouth inclination≤2.5mm

Physical and mechanical properties
 
Stacking inclination: stacking for 7 days, no collapse, no obvious tilt
Anti-fall: Add water to the marked capacity, naturally fall from a height of 1.5m to a horizontal rigid smooth surface, and must not break
Sealing: the barrel mouth and the barrel lid should be suitably matched, the barrel with a screw lid, the barrel and the lid should not slip after screwing, and the whole container should be able to withstand the negative pressure of 27KPa after closing.
Particulate contamination≥ 10 μm ≤ 6 pcs/ml
≥ 25 μm ≤ 1 pcs/ml
Microbial limitsThe total number of aerobic bacteria ≤ 50CFU/pcs
Mold and yeast ≤ 50CFU/pcs
Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa should not be detected

 